Automated External Defibrillator- (AED 7000)

60,000.00

Description:

The AED 7000 (Automated External Defibrillator) is a defibrillation device that is both safe and convenient to use. It can be used in the home or in public to provide first assistance for sudden death symptoms.

Description

AUTOMATED EXTERNAL DEFIBRILLATOR- (AED 7000)

The AED 7000 (Automated External Defibrillator) is a defibrillation device that is both safe and convenient to use. It can be used in the home or in public to provide first assistance for sudden death symptoms. When used in conjunction with advanced ECG analytical techniques, the defibrillator can not only analyses the patient’s ECG, make a decision for the patient’s cardiac monitor, and indicate whether defibrillation is necessary, but it can also reduce the defibrillation’s heart injury to the greatest extent possible. The operator is under no obligation to utilize the device. The defibrillator will provide voice prompts to help the operator through the defibrillation procedure step by step, as well as a safety alert if the need arises.

Automated External Defibrillator- (AED 7000) Features:

  • Defibrillation in three steps
  • Operation with two buttons
  • For the operator, there are a lot of voice and visual instructions.
  • For reporting each use to a printer or computer, a continuous event recording system is used.
  • Self-assessment on a weekly basis to guarantee readiness
  • Energy production that is biphasic
  • Defibrillation lockout to prevent unintentional defibrillation

Automated External Defibrillator- (AED 7000) Specifications:

 Defibrillator:

  • Output: Biphasic Truncated exponential
  • Energy Sequence: 150, 150, 200J
  • Charge Time: 8 sec. to150J
  • 10 sec. to 200 J(NEW battery)
  • Analysis Time: 9 sec.
  • The maximum time from the initiation of rhythm analysis to readiness for discharge with a new battery: Less than 30 seconds
  • The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocks: Less than 35 seconds
  • The maximum time from the initiation of rhythm analysis to readiness for discharge: Less than 25 seconds
  • Audible Prompts: 20 audible prompts
  • Visual Prompts: LED prompts
  • Controls: Two buttons – On/Off, Shock
  • Output Energy Accuracy: ±15% into impedance from 25 to 75Ω
  • The Maximum Voltage: 1200±50V
  • Output disabled when the patient impedance is outside limits: 20Ω to 200 Ω

Battery:

  • Part No: CR123A-4X2
  • Non-Rechargeable: 12V DC. 3.0 Ah
  • Capacity: 100 discharges at 200 Joules or 120 discharges at 150 Joules
  • Shelf Life (25℃±15℃): 10 years (5 years storage + 5 years standby)
  • 5 years standby (after installation)

Physical:

  • Dimensions: 303 X 216 X 89 mm
  • Weight: 2 kg
  • Operating Temperature 0℃ to 40℃
  • Operating Humidity: Relative humidity between 30% and 95% (non-condensing)
  • Storage Temperature: -20℃ to 55℃ (without battery)
  • Storage Humidity: Up to 93% (non-condensing) (without battery)